Cold Storage Solar: Planning Solar for Refrigerated Warehouses in Los Angeles and the San Fernando Valley

Cold storage solar for LA and San Fernando Valley refrigerated warehouses: energy use, daytime load fit, demand charges, storage, and LADWP vs SCE exports.

Short answer

Few commercial buildings use electricity like a refrigerated warehouse. Compressors, evaporator fans, defrost cycles and dock doors keep running through nights, weekends and holidays, because product has to stay cold whether or not anyone is in the building. That makes cold storage one of the most electricity-intensive property types an owner can hold, and one where solar deserves a careful look. This guide covers what the federal data says about refrigerated warehouse energy use, how that load lines up with solar production, where battery storage and demand charges come in, and how the rules differ between LADWP and SCE.

Aerial view of a Current Energy commercial solar installation at a food distributor

How much electricity does a refrigerated warehouse use?

The best national benchmark is the U.S. Energy Information Administration's Commercial Buildings Energy Consumption Survey (CBECS). In the 2018 survey, refrigerated warehouses averaged 29.6 kWh of electricity per square foot per year, while non-refrigerated warehouses averaged 5.3 kWh per square foot (EIA CBECS 2018, Table C22). Refrigerated buildings were among the most electricity-intensive warehouse types in the survey.

Keep in mind that these are national averages from a survey sample. Your building's real number depends on storage temperature (cooler vs. freezer), insulation, door traffic, equipment age and how the facility runs. The only reliable starting point for any solar design is your own interval data and 12 months of utility bills.

Why the cold storage load fits solar

Most solar projects run into a timing problem: the building uses the most power when the sun isn't up. Refrigerated warehouses are different in two ways.

  1. The load runs all the time. Refrigeration doesn't shut off at night, so there's a steady base load that solar production can offset during the day instead of exporting it.
  2. Cooling demand tends to rise in the heat of the day. On hot afternoons in the San Fernando Valley or the Inland Empire, compressors work harder to reject heat, and that's also when solar panels are producing. A system sized to your daytime load can serve more of its output on site.

There's also a well-documented flexibility advantage. Research for the California Energy Commission by Lawrence Berkeley National Laboratory found that refrigerated warehouses can shift load through pre-cooling and capacity limiting, and shed load through measures such as demand defrost and lighting reduction (Refrigerated Warehouse Demand Response Strategy Guide). Thermal mass in a well-insulated freezer works a little like a battery: a facility can pre-cool while solar is producing and coast through part of the evening, within the product's temperature limits.

Demand charges and battery storage

Many commercial and industrial customers pay demand charges, which are based on their highest power draw (kW) in a billing period, on top of charges for energy (kWh). A survey by Lawrence Berkeley National Laboratory and NREL estimated that nearly 5 million U.S. commercial customers can be on tariffs with demand charges above $15 per kW (LBNL/NREL demand charge survey).

Solar alone has limits on demand charges. A passing cloud or an evening peak can still set the monthly maximum. NREL's analysis across 15 commercial building types and 15 U.S. cities, including Los Angeles, found that solar paired with storage tends to reduce billing demand more than either one alone, though results vary widely by building, location and system size (NREL). A separate NREL study found that solar-plus-storage is more often economical under time-of-use and demand-charge rates, and named California as a near-term market (NREL/OSTI). Neither study modeled refrigerated warehouses specifically, so treat them as directional, not predictive.

For cold storage, a battery can also do things that don't show up on the bill:

  • carry critical refrigeration through short outages, depending on how the system is designed and sized;
  • cover the hours after sunset, when refrigeration is still running; and
  • smooth compressor start-up spikes that can set demand peaks.

Whether storage makes sense for your facility depends on your rate schedule, your interval data and your operating priorities. See our commercial battery storage page for how we approach those systems.

LADWP vs SCE: how exported solar is credited

Cold storage operators in Los Angeles County are usually served by either LADWP or Southern California Edison. Your bill says which one. (If you're not sure what that means for your property, our LADWP vs SCE solar guide explains how to check.) For a refrigerated building, the main question is how any power you export gets valued, because that drives system size.

LADWP: net metering at your rate's energy pricing, up to 1 MW

Under LADWP's Net Energy Metering Rider, a customer-owned solar system of not more than one megawatt on the customer's premises, intended primarily to offset the customer's own use, can net-meter. When the system generates more than the building uses in a billing period, LADWP calculates a credit for the excess "using the applicable Rate Schedule energy pricing." Credit balances roll forward to later bills (excluding taxes and minimum charges), apply only to the meter that measured the excess, and go to zero when service ends.

Because cold storage uses so much power, many LADWP refrigerated buildings will use most of their solar production on site. A system within the 1 MW limit, sized to the building's load, can offset energy charges at the rate's energy pricing.

If the building has more roof or parking area than its own load can use, LADWP also offers a separate path. Under the LADWP Feed-in Tariff, the output is sold to LADWP under a long-term contract instead of being used on site, subject to program capacity and LADWP acceptance.

SCE: the Solar Billing Plan pays hourly export values

New SCE solar customers are on the Solar Billing Plan. Your building uses its solar power first. Excess energy sent to the grid earns Energy Export Credits whose values change with the time of day and season, calculated using a CPUC method. SCE says credits tend to be higher from 4 to 9 p.m. and in summer months, and lower from 6 a.m. to 4 p.m., when solar is plentiful. SCE also explains that export credits are meant to offset eligible charges, not to create income from excess generation, and that some credits can be adjusted at the annual true-up.

For a cold storage building in SCE territory, that usually means:

  • sizing solar to on-site load, so that daytime production goes to compressors and not to low-value midday exports; and
  • looking at storage to move some midday production into the evening, when export values and grid prices tend to be higher.

Side by side

LADWP SCE
Program Net Energy Metering Rider Solar Billing Plan
Size limit noted Not more than 1 MW, customer-owned, on premises Sized to on-site needs
Export credit Applicable rate schedule energy pricing Hourly Energy Export Credits, vary by time and season
Design implication Offset on-site use; FiT is a separate option for extra area Maximize self-consumption; consider storage

Program rules as published by LADWP and SCE as of October 2026. They can change; verify current terms with your utility.

What a cold storage solar assessment looks at

Every refrigerated building is different, so a responsible evaluation starts with data, not a module count:

  • Interval data and bills. Twelve months of usage, plus 15-minute interval data if available, to see the base load, afternoon peaks and demand charges.
  • Roof condition and structure. Freezer buildings often have heavy insulated roof assemblies and rooftop condensing units. The roof has to carry the array and outlast it. Our roof readiness checklist covers what to look for.
  • Parking and canopy options. If the roof is crowded with equipment, carports or canopies may be the better fit. That's the approach used at our Vitco Foods project, a perishable food distributor.
  • Electrical service and switchgear. Refrigeration plants often sit on large services. Interconnection has to work with the existing gear.
  • Operations. Defrost schedules, pre-cooling flexibility and backup power needs all affect design and storage decisions.

Federal tax credit timing

Commercial solar and paired storage may qualify for the federal investment tax credit: up to 30% federal tax credit (6% base; 30% if prevailing wage and apprenticeship rules are met; eligibility varies, consult a tax advisor). Projects must be placed in service by Dec 31, 2027. Subject to eligibility. For what "placed in service" means and why schedules matter, read our commercial solar tax credit deadline post.

Work with a team built for large commercial loads

Current Energy has 200+ MW designed, engineered and installed across commercial, industrial and multifamily properties in Southern California. Big jobs need specialized skills and resources. We have both. We'll review your load, roof, parking area, utility rules and storage options, and tell you plainly what we think fits. Learn more about our commercial solar services.

Get a free site assessment or call (888) 899-9484. Have 12 months of utility bills ready, plus interval data if you can get it.

Frequently asked questions

Is solar a good fit for cold storage facilities?

Often it's worth evaluating. Refrigerated warehouses use far more electricity per square foot than non-refrigerated ones (29.6 vs. 5.3 kWh per square foot per year in EIA's 2018 CBECS), and they run a steady load during daylight hours. Fit depends on your load data, roof or parking area, utility and rate.

Should a refrigerated warehouse add battery storage?

It depends. Storage can help manage demand charges, cover evening refrigeration and support critical loads during outages, depending on design. NREL research suggests solar plus storage tends to reduce billing demand more than either alone, but results vary by site and rate.

How does LADWP credit excess solar from a commercial building?

Under LADWP's Net Energy Metering Rider, customer-owned systems up to 1 MW that mainly offset your own use receive credit for excess energy at your rate schedule's energy pricing. Credits roll forward but apply only to the meter that recorded them.

What changes for cold storage in SCE territory?

New SCE solar customers are on the Solar Billing Plan, where exports earn hourly credits that are typically lower midday and higher from 4 to 9 p.m. That favors sizing solar to on-site load and considering storage to shift energy into the evening.

Disclaimer: This article is for general informational purposes only and is not legal, tax, accounting, financial or engineering advice. Tax credits, incentives, utility programs, rates and rules are set by government agencies and utilities, are complex, and can change at any time; eligibility depends on your specific facts. Figures and program details are as published by the cited sources on the date noted and may not be current. Consult your own tax advisor, attorney and other qualified professionals before making decisions. Current Energy does not guarantee eligibility, savings, incentive amounts, approvals or timelines. Nothing in this article is an offer or commitment by Current Energy; any offer or commitment exists only in a written agreement signed by all parties.

Work with a team built for large commercial loads

We’ll review your load, roof, parking area, utility rules and storage options, and tell you plainly what we think fits.

Get a free consultation

Solar, battery storage, EV charging, lighting, HVAC and more. Tell us about your project.

Services of interest (tick all that apply)
Preferred contact method *

Optional. We still reply if you leave this unticked — consent to be texted is never required to get a quote.

No cost, no obligation.

Call now Free assessment