Published November 2026Battery storage

How to Reduce Demand Charges: A Guide for LA and SoCal Business Owners

Learn how to reduce demand charges on an SCE or LADWP business bill: what sets your peak kW, why solar alone may not lower it, and where battery storage helps.

Rooftop and carport solar on an industrial building, a Current Energy commercial project
Rooftop and carport solar on an industrial building, a Current Energy project.

Short answer: To reduce demand charges, you lower the highest burst of power your building pulls from the grid in a billing period, not just the total energy you use. That usually means three things: find what sets your peak from 15-minute interval data, stagger or schedule the equipment that causes it, and, where the numbers work, add battery storage that discharges during those spikes. Solar lowers the energy you buy, but on its own it may not lower your peak. The right mix depends on your utility, rate schedule and load pattern.

This guide is for owners and operators of warehouses, manufacturing sites, offices and other commercial buildings served by Southern California Edison or LADWP.

What a demand charge actually is

Most business bills have two kinds of charges:

  • Energy charges are based on kilowatt-hours (kWh), the total electricity you use.
  • Demand charges are based on kilowatts (kW), the highest rate at which you draw power during the billing period.

SCE explains it with light bulbs: one bulb on for 10 hours and 10 bulbs on for one hour use the same energy, but the second case needs far more grid capacity at once (SCE). Demand charges pay for that capacity.

A national survey by Lawrence Berkeley National Laboratory and NREL estimated that nearly 5 million U.S. commercial customers can be on tariffs with demand charges above $15 per kW (LBNL/NREL). For many buildings, it's one of the biggest lines on the bill.

How SCE and LADWP measure your peak

The two utilities that serve most of Los Angeles County count demand differently, and that changes the strategy.

SCE: two kinds of demand charges

On many SCE business time-of-use rates you'll see:

  • Facilities-Related Demand (FRD): based on your highest recorded kW in the billing month, at any time of day.
  • Time-Related Demand (TRD): based on your highest kW during On-Peak hours in summer and Mid-Peak hours in winter, on non-holiday weekdays.

Both definitions come from SCE's business rate page. Some SCE rates also offer options that trade demand charges against energy charges. For example, the TOU-8 fact sheet describes an Option DD for customers with behind-the-meter battery storage, with lower demand charges and higher energy charges (SCE TOU-8 fact sheet). Whether an option like that helps you is a modeling question, not a rule of thumb.

LADWP: one spike can follow you for a year

LADWP measures maximum demand as your average load during the 15-minute period of greatest use in the billing month. On its large commercial rates, the monthly demand charge uses that month's peak, while the facilities charge is based on the highest demand recorded in the last 12 months (LADWP rates).

That second part matters. LADWP says the facilities charge stays on every bill and adjusts only as your 12-month peak changes (LADWP News). So one bad 15-minute window, like a summer afternoon when every compressor and chiller started at once, can raise that charge for months afterward.

Not sure which utility serves your building? Our LADWP vs SCE guide explains how to tell.

Step 1: Find what sets your peak

You can't lower a peak you can't see. Start with:

  1. Twelve months of bills, to see your demand charges and when they peaked.
  2. 15-minute interval data, which most commercial customers can request from their utility. It shows exactly when the spikes happen.
  3. An equipment list and shift schedule, so spikes can be matched to what was running.

Common causes include large motors and compressors starting together, HVAC and process loads overlapping on hot afternoons, EV chargers added without load management, and shift changes where equipment powers up all at once.

Step 2: Reduce peaks without new equipment

Some of the cheapest wins are operational:

  • Stagger startups of large motors, compressors and HVAC units instead of starting them together.
  • Shift flexible loads, like charging forklifts or running batch processes, away from your peak window.
  • Add load management to EV charging so chargers share capacity instead of all drawing at full power.
  • Check controls and settings on HVAC and process equipment, which can cause avoidable spikes after a reset.

These won't fit every operation, but they're worth checking before you buy anything.

Step 3: Peak shaving with battery storage

Peak shaving means a battery discharges during the moments your building would otherwise hit a new peak, so the grid sees a lower maximum. It's the main reason many businesses look at commercial battery storage.

A few things decide whether it pays:

  • How sharp your peaks are. Short, predictable spikes are easier for a battery to cover than long, flat high loads.
  • Your rate structure. Monthly peaks, time-of-use demand windows and a 12-month facilities charge each reward a different dispatch plan.
  • Controls. The battery has to discharge at the right moment. A missed 15-minute window can set the peak anyway.
  • Other uses. The same battery may also store midday solar for evening use or back up critical loads, depending on design.

Why solar alone may not cut demand charges

Solar is excellent at lowering the kWh you buy during the day. Demand charges are harder. A passing cloud, an early-evening peak or a late-shift startup can still set the month's maximum when solar output is low.

NREL's analysis of 15 commercial building types across 15 U.S. cities, including Los Angeles, found that solar paired with storage tends to reduce billing demand more than either one alone, though results vary widely by building, location and system size (NREL). Treat that as directional, not a prediction for your site.

If you're on SCE, storage also matters for how solar exports are credited. Our post on SCE's Solar Billing Plan for commercial properties covers that side.

Tax credits and timing

A business-owned system may qualify for an up to 30% federal tax credit (6% base; 30% if prevailing wage and apprenticeship rules are met; eligibility varies, consult a tax advisor). For the solar portion of a project, projects must be placed in service by Dec 31, 2027. Subject to eligibility. Rules for battery storage are not the same as for solar, so ask your tax advisor how they apply to your project before you plan around them. See our commercial solar page for how we approach business projects.

FAQ

What is the fastest way to reduce demand charges?

Look at your 15-minute interval data and find what runs during your highest spikes. Staggering startups or shifting flexible loads can lower peaks without new equipment. Battery storage helps when the peaks are short and predictable.

Can solar panels lower demand charges?

Sometimes, but not reliably on their own. Your peak can still be set when solar output is low, like on a cloudy afternoon or in the early evening. Pairing solar with storage tends to do better, according to NREL research.

Why is my LADWP facilities charge still high after a slow month?

On LADWP's large commercial rates, the facilities charge is based on your highest demand in the last 12 months, not the current month. A single high peak can keep it elevated until it rolls out of that 12-month window.

Is peak shaving worth it for a small business?

It depends on your rate. Smaller accounts are often on rates with little or no demand charge, so there may be less to save. We check your bill first and tell you if it's not worth pursuing.

Get a demand charge review

Current Energy designs commercial solar and battery storage for buildings across Los Angeles County and the San Fernando Valley. Send us 12 months of bills, plus interval data if you have it, and we'll show you what's setting your peak and whether storage, solar or simple scheduling changes make sense.

Call (888) 899-9484 or request a free assessment.

This article is general information, not tax, legal or rate advice. Utility rates and rules change; check your current tariff.

Disclaimer: This article is for general informational purposes only and is not legal, tax, accounting, financial or engineering advice. Tax credits, incentives, utility programs, rates and rules are set by government agencies and utilities, are complex, and can change at any time; eligibility depends on your specific facts. Figures and program details are as published by the cited sources on the date noted and may not be current. Consult your own tax advisor, attorney and other qualified professionals before making decisions. Current Energy does not guarantee eligibility, savings, incentive amounts, approvals or timelines. Nothing in this article is an offer or commitment by Current Energy; any offer or commitment exists only in a written agreement signed by all parties.

Want to know what’s setting your peak?

Send us your bills. We’ll look at your demand charges and tell you plainly whether scheduling, storage or solar makes sense for your building.

Get a free consultation

Solar, battery storage, EV charging, lighting, HVAC and more. Tell us about your project.

Services of interest (tick all that apply)
Preferred contact method *

Optional. We still reply if you leave this unticked — consent to be texted is never required to get a quote.

No cost, no obligation.

Call now Free assessment